29 CFR 1926.704
§ 1926.704 Requirements for precast concrete.
United States · 29 CFR — Labor · Status: effective
Cite this
- Citation
- 29 CFR 1926.704, § 1926.704 Requirements for precast concrete, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/129294
- Permanent ID
ys:prov:129294@1- SHA-256
42e1926affdb880da9430b04e4cdb0fbadd63ae2dd2be4a5c6daf605d06b4f86
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Precast concrete wall units, structural framing, and tilt-up wall panels shall be adequately supported to prevent overturning and to prevent collapse until permanent connections are completed.
(b) Lifting inserts which are embedded or otherwise attached to tilt-up precast concrete members shall be capable of supporting at least two times the maximum intended load applied or transmitted to them.
(c) Lifting inserts which are embedded or otherwise attached to precast concrete members, other than the tilt-up members, shall be capable of supporting at least four times the maximum intended load applied or transmitted to them.
(d) Lifting hardware shall be capable of supporting at least five times the maximum intended load applied or transmitted to the lifting hardware.
(e) No employee shall be permitted under precast concrete members being lifted or tilted into position except those employees required for the erection of those members.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.