29 CFR 1926.904
§ 1926.904 Storage of explosives and blasting agents.
United States · 29 CFR — Labor · Status: effective
Cite this
- Citation
- 29 CFR 1926.904, § 1926.904 Storage of explosives and blasting agents, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/129343
- Permanent ID
ys:prov:129343@1- SHA-256
adaf560b0f0b56d831fcd97149adc62f98856445fbe0205f11b486228edbf8b2
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Explosives and related materials shall be stored in approved facilities required under the applicable provisions of the Bureau of Alcohol, Tobacco and Firearms regulations contained in 27 CFR part 55, Commerce in Explosives.
(b) Blasting caps, electric blasting caps, detonating primers, and primed cartridges shall not be stored in the same magazine with other explosives or blasting agents.
(c) Smoking and open flames shall not be permitted within 50 feet of explosives and detonator storage magazine.
(d) No explosives or blasting agents shall be permanently stored in any underground operation until the operation has been developed to the point where at least two modes of exit have been provided.
(e) Permanent underground storage magazines shall be at least 300 feet from any shaft, adit, or active underground working area.
(f) Permanent underground magazines containing detonators shall not be located closer than 50 feet to any magazine containing other explosives or blasting agents.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.