yourstate.us
29 CFR 1926.907

§ 1926.907 Use of safety fuse.

United States · 29 CFR — Labor · Status: effective

Get this as JSONEmbed this
Cite this
Citation
29 CFR 1926.907, § 1926.907 Use of safety fuse, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/129346
Permanent ID
ys:prov:129346@1
SHA-256
9c480fb618de837a11ee58b8201c777a41b2e8e7621ad620372b2267177cadae

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Safety fuse shall only be used where sources of extraneous electricity make the use of electric blasting caps dangerous. The use of a fuse that has been hammered or injured in any way shall be forbidden. (b) The hanging of a fuse on nails or other projections which will cause a sharp bend to be formed in the fuse is prohibited. (c) Before capping safety fuse, a short length shall be cut from the end of the supply reel so as to assure a fresh cut end in each blasting cap. (d) Only a cap crimper of approved design shall be used for attaching blasting caps to safety fuse. Crimpers shall be kept in good repair and accessible for use. (e) No unused cap or short capped fuse shall be placed in any hole to be blasted; such unused detonators shall be removed from the working place and destroyed. (f) No fuse shall be capped, or primers made up, in any magazine or near any possible source of ignition. (g) No one shall be permitted to carry detonators or primers of any kind on his person. (h) The minimum length of safety fuse to be used in blasting shall be as required by State law, but shall not be less than 30 inches. (i) At least two men shall be present when multiple cap and fuse blasting is done by hand lighting methods. (j) Not more than 12 fuses shall be lighted by each blaster when hand lighting devices are used. However, when two or more safety fuses in a group are lighted as one by means of igniter cord, or other similar fuse-lighting devices, they may be considered as one fuse. (k) The so-called “drop fuse” method of dropping or pushing a primer or any explosive with a lighted fuse attached is forbidden. (l) Cap and fuse shall not be used for firing mudcap charges unless charges are separated sufficiently to prevent one charge from dislodging other shots in the blast. (m) When blasting with safety fuses, consideration shall be given to the length and burning rate of the fuse. Sufficient time, with a margin of safety, shall always be provided for the blaster to reach a place of safety.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.