§ 57.6402 Deenergized circuits near detonators.
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 57.6402, § 57.6402 Deenergized circuits near detonators, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/132804
- Permanent ID
ys:prov:132804@1- SHA-256
f70f56ed3b8f342468d08be4fdf03c160e86cd807e8a16dbf7e6ae07ec5dc1ed
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Electrical distribution circuits within 50 feet of electric detonators at the blast site shall be deenergized. Such circuits need not be deenergized between 25 to 50 feet of the electric detonators if stray current tests, conducted as frequently as necessary, indicate a maximum stray current of less than 0.05 ampere through a 1-ohm resistor as measured at the blast site.