yourstate.us
30 CFR 57.19024

§ 57.19024 Retirement criteria.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 57.19024, § 57.19024 Retirement criteria, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133132
Permanent ID
ys:prov:133132@1
SHA-256
14473b49c32ef21e88223fa33275b28247553c8c00a98d260e34266d458c9afb

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Unless damage or deterioration is removed by cutoff, wire ropes shall be removed from service when any of the following conditions occurs: (a) The number of broken wires within a rope lay length, excluding filler wires, exceeds either— (1) Five percent of the total number of wires; or (2) Fifteen percent of the total number of wires within any strand. (b) On a regular lay rope, more than one broken wire in the valley between strands in one rope lay length. (c) A loss of more than one-third of the original diameter of the outer wires. (d) Rope deterioration from corrosion. (e) Distortion of the rope structure. (f) Heat damage from any source. (g) Diameter reduction due to wear that exceeds six percent of the baseline diameter measurement. (h) Loss of more than ten percent of rope strength as determined by nondestructive testing.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.