30 CFR 57.22205
§ 57.22205 Doors on main fans (I-A, II-A, III, and V-A mines).
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 57.22205, § 57.22205 Doors on main fans (I-A, II-A, III, and V-A mines), United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133231
- Permanent ID
ys:prov:133231@1- SHA-256
c645ea884e06fb8f25b899076e0e78de0d78b21361efbcc1ce639f50aa13f6ec
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
In mines ventilated by multiple main fans, each main fan installation shall be equipped with noncombustible doors. Such doors shall automatically close to prevent air reversal through the fan. The doors shall be located so that they are not in direct line with explosive forces which could come out of the mine.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.