§ 57.22207 Booster fans (I-A, II-A, III, and V-A mines).

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 57.22207, § 57.22207 Booster fans (I-A, II-A, III, and V-A mines), United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133233
Permanent ID
ys:prov:133233@1
SHA-256
dc34e6f4e976d8005455e75f9a671d13c34dfcfb474d91e0d2015722722a5c98

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Booster fans shall be approved by MSHA under the applicable requirements of 30 CFR part 18, and be— (1) Provided with an automatic signal device located so that it can be seen or heard by a person designated by the mine operator to give an alarm when the fan stops or when methane reaches the following levels: (i) 1.0 percent at the fan in Subcategory I-A, Category III, and Subcategory V-A mines; and (ii) 0.5 percent at the fan in Subcategory II-A mines. (2) Equipped with a device that automatically deenergizes power in affected workings should the fan stop; and (3) Equipped with starting and stopping controls located at the fan and at another accessible remote location. (b) Booster fan installations, except for booster fans installed in ducts, shall be— (1) Provided with doors which open automatically when all fans in the installation stop; and (2) Provided with an air lock when passage through the fan bulkhead is necessary.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.