30 CFR 57.22216
§ 57.22216 Separation of intake and return air (I-C mines).
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 57.22216, § 57.22216 Separation of intake and return air (I-C mines), United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133242
- Permanent ID
ys:prov:133242@1- SHA-256
28519170e69a53068f3ca411bb1a84905518b08ab3a3a0580fd79dc6fd99b8ea
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The main intake and return air currents in single shafts shall be separated by ventilation tubing, curtain walls, or partitions. Ventilation tubing shall be constructed of noncombustible material. Curtain walls or partitions shall be constructed of reinforced concrete or other noncombustible equivalent, and provided with pressure-relief devices.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.