yourstate.us
30 CFR 75.516

§ 75.516 Power wires; support.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 75.516, § 75.516 Power wires; support, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133577
Permanent ID
ys:prov:133577@1
SHA-256
28db7efc408e2b5169770b2a38a1b48eb188c74a5c64023014f13108546910bb

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

All power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return wires) shall be supported on well-insulated insulators and shall not contact combustible material, roof, or ribs.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.