30 CFR 75.516-2
§ 75.516-2 Communication wires and cables; installation; insulation; support.
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 75.516-2, § 75.516-2 Communication wires and cables; installation; insulation; support, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133579
- Permanent ID
ys:prov:133579@1- SHA-256
692d91e16578b8a1e2518fb4d1fd88b6c13fa2383892cbe7d2db63a16d1281af
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) All communication wires shall be supported on insulated hangers or insulated J-hooks.
(b) All communication cables shall be insulated as required by § 75.517-1, and shall either be supported on insulated or uninsulated hangers or J-hooks, or securely attached to messenger wires, or buried, or otherwise protected against mechanical damage in a manner approved by the Secretary or his authorized representative.
(c) All communication wires and cables installed in track entries shall, except when a communication cable is buried in accordance with paragraph (b) of this section, be installed on the side of the entry opposite to trolley wires and trolley feeder wires. Additional insulation shall be provided for communication circuits at points where they pass over or under any power conductor.
(d) For purposes of this section, communication cable means two or more insulated conductors covered by an additional abrasion-resistant covering.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.