30 CFR 75.604
§ 75.604 Permanent splicing of trailing cables.
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 75.604, § 75.604 Permanent splicing of trailing cables, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133607
- Permanent ID
ys:prov:133607@1- SHA-256
3cef5b1d13bcdadf0b24bea9b85dac86d9dea349825e1cc9d8cc7e7229f0dacd
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
When permanent splices in trailing cables are made, they shall be:
(a) Mechanically strong with adequate electrical conductivity and flexibility;
(b) Effectively insulated and sealed so as to exclude moisture; and
(c) Vulcanized or otherwise treated with suitable materials to provide flame-resistant qualities and good bonding to the outer jacket.
(d) Made using splice kits accepted or approved by MSHA as flame resistant.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.