30 CFR 75.822
§ 75.822 Underground high-voltage longwall cables.
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 75.822, § 75.822 Underground high-voltage longwall cables, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133673
- Permanent ID
ys:prov:133673@1- SHA-256
a3840ebbc242853df98b66e34c74efd021419048159f0d6423215680185bebbe
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
In addition to the high-voltage cable design specifications in § 75.804 of this part, high-voltage cables for use on longwalls may be a type SHD cable with a center ground-check conductor no smaller than a No. 16 AWG stranded conductor. The cables must be MSHA accepted as flame-resistant under part 18 or approved under subpart K of part 7.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.