yourstate.us
30 CFR 75.906

§ 75.906 Trailing cables for mobile equipment, ground wires, and ground check wires.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 75.906, § 75.906 Trailing cables for mobile equipment, ground wires, and ground check wires, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/133701
Permanent ID
ys:prov:133701@1
SHA-256
9cd2351067ececa35ec8671ee7674b2cf3b4935a7b1072f2c0f5546a41018035

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

Trailing cables for mobile equipment shall contain one or more ground conductors having a cross-sectional area of not less than one-half the power conductor, and, on September 30, 1970, an insulated conductor for the ground continuity check circuit or other no less effective device approved by the Secretary or his authorized representative to assure such continuity, except that an extension of time, not in excess of 12 months may be permitted by the Secretary on a mine-by-mine basis if he determines that such equipment is not available. Splices made in the cables shall provide continuity of all components.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.