yourstate.us
30 CFR 77.906

§ 77.906 Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check wires.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 77.906, § 77.906 Trailing cables supplying power to low-voltage mobile equipment; ground wires and ground check wires, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134127
Permanent ID
ys:prov:134127@1
SHA-256
b2ed804cd0d659e803f1d2afe7bc15ed0cac1b4b705b5f9ddbc08c71b916e998

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

On and after September 30, 1971, all trailing cables supplying power to portable or mobile equipment from low-voltage three-phase resistance grounded power systems shall contain one or more ground conductors having a cross-sectional area of not less than one-half the power conductor. Such trailing cables shall include an insulated conductor for the ground continuity check circuit except where a no less effective device has been approved by the Secretary to assure continuity. Splices made in low-voltage trailing cables shall provide continuity of all components.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.