30 CFR 77.1914
§ 77.1914 Electrical equipment.
United States · 30 CFR — Mineral Resources · Status: effective
Cite this
- Citation
- 30 CFR 77.1914, § 77.1914 Electrical equipment, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134243
- Permanent ID
ys:prov:134243@1- SHA-256
2e409f1853255a920fcec3ad332967af7db03904052be5b02b236f096a30294f
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Electric equipment employed below the collar of a slope or shaft during excavation shall be permissible and shall be maintained in a permissible condition.
(b) The insulation of all electric conductors employed below the collar of any slope or shaft during excavation shall be of the flame resistant type.
(c) Only lamps and portable flood lights approved by the Bureau of Mines or the Mine Safety and Health Administration under Part 19 and Part 20 of this chapter (Bureau of Mines Schedules 6D and 10C) shall be employed below the collar of any slope or shaft.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.