§ 250.431 What are the diverter design and installation requirements?

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 250.431, § 250.431 What are the diverter design and installation requirements?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134512
Permanent ID
ys:prov:134512@1
SHA-256
72b752acaeb65d9def54d70482f3105a0e03cfcee98b061add051f9ac18e9260

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

You must design and install your diverter system to: (a) Use diverter spool outlets and diverter lines that have a nominal diameter of at least 10 inches for surface wellhead configurations and at least 12 inches for floating drilling operations; (b) Use dual diverter lines arranged to provide for downwind diversion capability; (c) Use at least two diverter control stations. One station must be on the drilling floor. The other station must be in a readily accessible location away from the drilling floor; (d) Use only remote-controlled valves in the diverter lines. All valves in the diverter system must be full-opening. You may not install manual or butterfly valves in any part of the diverter system; (e) Minimize the number of turns (only one 90-degree turn allowed for each line for bottom-founded drilling units) in the diverter lines, maximize the radius of curvature of turns, and target all right angles and sharp turns; (f) Anchor and support the entire diverter system to prevent whipping and vibration; and (g) Protect all diverter-control instruments and lines from possible damage by thrown or falling objects.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.