yourstate.us
30 CFR 250.836

§ 250.836 Use of BSDVs.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 250.836, § 250.836 Use of BSDVs, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134648
Permanent ID
ys:prov:134648@1
SHA-256
4db2aa09ff30efd2005c912c57f7ad87a4baf85ba693b07799ffb3a61727f510

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

You must install, inspect, maintain, repair, and test all new BSDVs, as well as all BSDVs that you remove from service for remanufacturing or repair, in accordance with API STD 6AV2 (incorporated by reference in § 250.198) for SSVs. If any BSDV does not operate properly or if any gas fluid and/or liquid fluid flow is observed during the leakage test, as described in § 250.880, you must shut-in all sources to the BSDV and immediately repair or replace the valve.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.