§ 250.857 Glycol dehydration units.

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 250.857, § 250.857 Glycol dehydration units, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134663
Permanent ID
ys:prov:134663@1
SHA-256
3eba24711f40f2eec79f770c31b4f43bfe6436aaed40b43dbf96f93022ac4197

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) You must install a pressure relief system or an adequate vent on the glycol regenerator (reboiler) to prevent over pressurization. The discharge of the relief valve must be vented in a nonhazardous manner. (b) You must install the FSV on the dry glycol inlet to the glycol contact tower as near as practical to the glycol contact tower. (c) You must install the shutdown valve (SDV) on the wet glycol outlet from the glycol contact tower as near as practical to the glycol contact tower.