yourstate.us
30 CFR 250.919

§ 250.919 What in-service inspection requirements must I meet?

United States · 30 CFR — Mineral Resources · Status: effective

Get this as JSONEmbed this
Cite this
Citation
30 CFR 250.919, § 250.919 What in-service inspection requirements must I meet?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/134709
Permanent ID
ys:prov:134709@1
SHA-256
1bce95da0054a93203c10497d92c97e77a04fac2fe5b2234becc63d169d7efdd

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) You must submit a comprehensive in-service inspection report annually by November 1 to the Regional Supervisor that must include: (1) A list of fixed and floating platforms you inspected in the preceding 12 months; (2) The extent and area of inspection for both the above-water and underwater portions of the platform and the pertinent components of the mooring system for floating platforms; (3) The type of inspection employed (e.g., visual, magnetic particle, ultrasonic testing); (4) The overall structural condition of each platform, including a corrosion protection evaluation; and (5) A summary of the inspection results indicating what repairs, if any, were needed. (b) If any of your structures have been exposed to a natural occurrence (e.g., hurricane, earthquake, or tropical storm), the Regional Supervisor may require you to submit an initial report of all structural damage, followed by subsequent updates, which include the following: (1) A list of affected structures; (2) A timetable for conducting the inspections described in section 14.4.3 of API RP 2A-WSD (as incorporated by reference in § 250.198); and (3) An inspection plan for each structure that describes the work you will perform to determine the condition of the structure. (c) The Regional Supervisor may also require you to submit the results of the inspections referred to in paragraph (b)(2) of this section, including a description of any detected damage that may adversely affect structural integrity, an assessment of the structure's ability to withstand any anticipated environmental conditions, and any remediation plans. Under §§ 250.900(b)(3) and 250.905, you must obtain approval from BSEE before you make major repairs of any damage unless you meet the requirements of § 250.900(c).

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.