7 CFR 42.132
§ 42.132 Determining cumulative sum values.
United States · 7 CFR — Agriculture · Status: effective
Cite this
- Citation
- 7 CFR 42.132, § 42.132 Determining cumulative sum values, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/14696
- Permanent ID
ys:prov:14696@1- SHA-256
0326fee971c1b323e5e0b3e30bbbdae5c6b6e31188fcffa6fff610d63c41ac11
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The parameters for the on-line cumulative sum sampling plans for AQL's applicable to origin inspection are as follows:
(b) At the beginning of the basic inspection period, the CuSum value is set equal to the starting value (“S”) for the specified CuSum plan. The CuSum value is then determined for each consecutive subgroup as follows:
(1) Add the number of defects for the present subgroup to the CuSum value of the previous subgroup.
(2) Subtract the subgroup tolerance (“T”).
(3) The CuSum value is reset in the following situations; however, determine portion of production acceptability (see § 42.133) prior to resetting the CuSum value:
(i) Reset the CuSum value to zero (0) if the CuSum value is less than zero (0).
(ii) Reset the CuSum value to the acceptance limit (“L”) if the CuSum value exceeds the acceptance limit (“L”).