33 CFR 175.23
§ 175.23 Serviceable condition.
United States · 33 CFR — Navigation and Navigable Waters · Status: effective
Cite this
- Citation
- 33 CFR 175.23, § 175.23 Serviceable condition, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/153227
- Permanent ID
ys:prov:153227@1- SHA-256
a1fc08aba40efa57369c9f8c3c3be38443a14fb641ea506a89ab4c9ef6f5cfe1
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
A PFD is considered to be in serviceable condition for purposes of § 175.21(a) only if the following conditions are met:
(a) No PFD may exhibit deterioration that could diminish the performance of the PFD, including—
(1) Metal or plastic hardware used to secure the PFD on the wearer that is broken, deformed, or weakened by corrosion;
(2) Webbings or straps used to secure the PFD on the wearer that are ripped, torn, or which have become separated from an attachment point on the PFD; or
(3) Any other rotted or deteriorated structural component that fails when tugged.
(b) In addition to meeting the requirements of paragraph (a) of this section, no inherently buoyant PFD, including the inherently buoyant components of a hybrid inflatable PFD, may exhibit—
(1) Rips, tears, or open seams in fabric or coatings, that are large enough to allow the loss of buoyant material;
(2) Buoyant material that has become hardened, non-resilient, permanently compressed, waterlogged, oil-soaked, or which shows evidence of fungus or mildew; or
(3) Loss of buoyant material or buoyant material that is not securely held in position.
(c) In addition to meeting the requirements of paragraph (a) of this section, an inflatable PFD, including the inflatable components of a hybrid inflatable PFD, must be equipped with—
(1) Except as provided in paragraph (d) of this section, a properly armed inflation mechanism, complete with a full inflation medium cartridge and all status indicators showing that the inflation mechanism is properly armed;
(2) Inflatable chambers that are all capable of holding air;
(3) Oral inflation tubes that are not blocked, detached, or broken;
(4) A manual inflation lanyard or lever that is not inaccessible, broken, or missing; and
(5) Inflator status indicators that are not broken or otherwise non-functional.
(d) The inflation system of an inflatable PFD need not be armed when the PFD is worn inflated and otherwise meets the requirements of paragraphs (a) and (c) of this section.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.