36 CFR 1192.53
§ 1192.53 Doorways.
United States · 36 CFR — Parks, Forests, and Public Property · Status: effective
Cite this
- Citation
- 36 CFR 1192.53, § 1192.53 Doorways, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/160860
- Permanent ID
ys:prov:160860@1- SHA-256
47e59b7f42b288b6d44b40a87f588d403a718981577dd81099d837042066ad26
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Clear width.
(1) Passenger doorways on vehicle sides shall have clear openings at least 32 inches wide when open.
(2) If doorways connecting adjoining cars in a multi-car train are provided, and if such doorway is connected by an aisle with a minimum clear width of 30 inches to one or more spaces where wheelchair or mobility aid users can be accommodated, then such doorway shall have a minimum clear opening of 30 inches to permit wheelchair and mobility aid users to be evacuated to an adjoining vehicle in an emergency.
(b) Signage. The International Symbol of Accessibility shall be displayed on the exterior of accessible vehicles operating on an accessible and rapid rail system unless all vehicles area accessible and are not marked by the access symbol. (See Fig. 6)
(c) Signals. Auditory and visual warning signals shall be provided to alert passengers of closing doors.
(d) Coordination with boarding platform—(1) Requirements. Where new vehicles will operate in new stations, the design of vehicles shall be coordinated with the boarding platform design such that the horizontal gap between each vehicle door at rest and the platform shall be no greater than 3 inches and the height of the vehicle floor shall be within plus or minus 5/8 inch of the platform height under all normal passenger load conditions. Vertical alignment may be accomplished by vehicle air suspension or other suitable means of meeting the requirement.
(2) Exception. New vehicles operating in existing stations may have a floor height within plus or minus 1 1/2 inches of the platform height. At key stations, the horizontal gap between at least one door of each such vehicle and the platform shall be no greater than 3 inches.
(3) Exception. Retrofitted vehicles shall be coordinated with the platform in new and key stations such that the horizontal gap shall be no greater than 4 inches and the height of the vehicle floor, under 50% passenger load, shall be within plus or minus 2 inches of the platform height.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.