yourstate.us
7 CFR 58.218

§ 58.218 Surge tanks.

United States · 7 CFR — Agriculture · Status: effective

Get this as JSONEmbed this
Cite this
Citation
7 CFR 58.218, § 58.218 Surge tanks, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/16087
Permanent ID
ys:prov:16087@1
SHA-256
59509742485e891c5f5afc02e7999955e189e0ae334026c3e386d9d2ef799e67

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

If surge tanks are used for hot milk, and temperatures of product including foam being held in the surge tank during processing, is not maintained at a minimum of 150 °F, then two or more surge tanks shall be installed with cross connections to permit flushing and cleaning during operation. Covers easily removable for cleaning shall be provided and used at all times.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.