§ 1192.81 Lighting.

United States · 36 CFR — Parks, Forests, and Public Property · Status: effective

Get this as JSONEmbed this
Cite this
Citation
36 CFR 1192.81, § 1192.81 Lighting, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/160872
Permanent ID
ys:prov:160872@1
SHA-256
e8b24be39e666525ba6ba4224737d6c9879952ed25299492a0ce95b7d7d0e92e

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Any stepwell or doorway with a lift, ramp or bridge plate immediately adjacent to the driver shall have, when the door is open, at least 2 footcandles of illumination measured on the step tread or lift platform. (b) Other stepwells, and doorways with lifts, ramps or bridge plates, shall have, at all times, at least 2 footcandles of illumination measured on the step tread or lift or ramp, when deployed at the vehicle floor level. (c) The doorways of vehicles not operating at lighted station platforms shall have outside lights which provide at least 1 footcandle of illumination on the station platform or street surface for a distance of 3 feet perpendicular to all points on the bottom step tread. Such lights shall be located below window level and shielded to protect the eyes of entering and exiting passengers.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.