40 CFR 60.3067
§ 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 60.3067, § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/172891
- Permanent ID
ys:prov:172891@1- SHA-256
10c82d9209139bbc7ec8c5fe65bffde70ce1b37f22b7155f0b00146635539cf8
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Use EPA Method 9 of Appendix A to this part or ASTM D7520-16 (incorporated by reference, see § 60.17), to determine compliance with the opacity limitation.
(b) Conduct an initial test for opacity as specified in § 60.8 within 180 days after the final compliance date in table 1 of this subpart.
(c) After the initial test for opacity, conduct annual tests no more than 12 months following the date of your previous test.
(d) If the air curtain incinerator has been out of operation for more than 12 months following the date of your previous test, then you must conduct a test for opacity upon startup of the unit.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.