40 CFR 60.5380
§ 60.5380 What standards apply to centrifugal compressor affected facilities?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 60.5380, § 60.5380 What standards apply to centrifugal compressor affected facilities?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/173126
- Permanent ID
ys:prov:173126@1- SHA-256
88469e98680b0840ef2e3158cd03b592c4d2d0e859dacc4e61a6aaf4ce00e20a
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
You must comply with the standards in paragraphs (a) through (d) of this section for each centrifugal compressor affected facility.
(a)(1) You must reduce VOC emissions from each centrifugal compressor wet seal fluid degassing system by 95.0 percent or greater.
(2) If you use a control device to reduce emissions, you must equip the wet seal fluid degassing system with a cover that meets the requirements of § 60.5411(b), that is connected through a closed vent system that meets the requirements of § 60.5411(a) and routed to a control device that meets the conditions specified in § 60.5412(a), (b) and (c). As an alternative to routing the closed vent system to a control device, you may route the closed vent system to a process.
(b) You must demonstrate initial compliance with the standards that apply to centrifugal compressor affected facilities as required by § 60.5410(b).
(c) You must demonstrate continuous compliance with the standards that apply to centrifugal compressor affected facilities as required by § 60.5415(b).
(d) You must perform the required notification, recordkeeping, and reporting as required by § 60.5420.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.