§ 62.15200 What must I do if I choose to monitor carbon dioxide instead of oxygen as a diluent gas?

United States · 40 CFR — Protection of Environment · Status: effective

Get this as JSONEmbed this
Cite this
Citation
40 CFR 62.15200, § 62.15200 What must I do if I choose to monitor carbon dioxide instead of oxygen as a diluent gas?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/174757
Permanent ID
ys:prov:174757@1
SHA-256
e12311a81e938ee4028b90f3f0fb1a49cee7b5725de58ebd5da43da4fa62233f

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

You must establish the relationship between oxygen and carbon dioxide during the initial evaluation of your continuous emission monitoring system. You may reestablish the relationship during annual evaluations. To establish the relationship use three procedures: (a) Use EPA Reference Method 3A or 3B in appendix A of 40 CFR part 60 to determine oxygen concentration at the location of your carbon dioxide monitor. (b) Conduct at least three test runs for oxygen. Make sure each test run represents a 1-hour average and that sampling continues for at least 30 minutes in each hour. (c) Use the fuel-factor equation in EPA Reference Method 3B to determine the relationship between oxygen and carbon dioxide.