40 CFR 63.9000
§ 63.9000 What emission limitations and work practice standards must I meet?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 63.9000, § 63.9000 What emission limitations and work practice standards must I meet?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/177461
- Permanent ID
ys:prov:177461@1- SHA-256
705e98e61ddb0f3365f77a55dc7b99655c9bd7fc8c1aa6e7fb167f9316997211
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) With the exceptions noted in paragraphs (c) and (d) of this section, you must meet the applicable emission limit and work practice standard in table 1 to this subpart for each emission stream listed under § 63.8990(b)(1) through (4) that is part of your affected source.
(b) With the exceptions noted in paragraph (c) of this section, you must meet the applicable operating limit in Table 2 to this subpart for each emission stream listed under § 63.8990(b)(1) through (3) that is part of your affected source.
(c) The emission streams listed in paragraphs (c)(1) through (4) of this section are exempt from the emission limitations, work practice standards, and all other requirements of this subpart.
(1) Emission streams from HCl storage tanks that never store liquid HCl product with a concentration of 30 weight percent or greater.
(2) Emission streams from HCl transfer operations that never load liquid HCl product with a concentration of 30 weight percent or greater.
(3) Emission streams from HCl wastewater operations.
(4) Emission streams from HCl process vents, HCl storage tanks, and HCl transfer operations that are also subject to 40 CFR part 63, subpart EEE, National Emission Standards for Hazardous Air Pollutants for Hazardous Waste Combustors, or 40 CFR 266.107, subpart H, Burning of Hazardous Waste in Boilers and Industrial Furnaces.
(d) The emission limits for HCl storage tanks in table 1 to this subpart do not apply during periods of planned routine maintenance of HCl storage tank control devices. Periods of planned routine maintenance of each HCl storage tank control device, during which the control device does not meet the emission limits specified in table 1 to this subpart, shall not exceed 240 hours per year.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.