§ 63.9921 What are the installation, operation and maintenance requirements for my monitors?

United States · 40 CFR — Protection of Environment · Status: effective

Get this as JSONEmbed this
Cite this
Citation
40 CFR 63.9921, § 63.9921 What are the installation, operation and maintenance requirements for my monitors?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/177628
Permanent ID
ys:prov:177628@1
SHA-256
d8ec62766bc40aac130ec1af339877ffc2b0e67f8a7d7d3a57824fc6204fc5b6

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) For each wet scrubber subject to the operating limits in § 63.9890(b) for pressure drop and scrubber water flow rate, you must install, operate, and maintain each CPMS according to the requirements in paragraphs (a)(1) and (2) of this section. (1) For the pressure drop CPMS, you must: (i) Locate the pressure sensor(s) in or as close to a position that provides a representative measurement of the pressure and that minimizes or eliminates pulsating pressure, vibration, and internal and external corrosion. (ii) Use a gauge with a minimum measurement sensitivity of 0.5 inch of water or a transducer with a minimum measurement sensitivity of 1 percent of the pressure range. (iii) Check the pressure tap for pluggage daily. (iv) Using a manometer, check gauge calibration quarterly and transducer calibration monthly. (v) Conduct calibration checks any time the sensor exceeds the manufacturer's specified maximum operating pressure range, or install a new pressure sensor. (vi) At least monthly, inspect all components for integrity, all electrical connections for continuity, and all mechanical connections for leakage. (2) For the scrubber water flow rate CPMS, you must: (i) Locate the flow sensor and other necessary equipment in a position that provides a representative flow and that reduces swirling flow or abnormal velocity distributions due to upstream and downstream disturbances. (ii) Use a flow sensor with a minimum measurement sensitivity of 2 percent of the flow rate. (iii) Conduct a flow sensor calibration check at least semiannually according to the manufacturer's instructions. (iv) At least monthly, inspect all components for integrity, all electrical connections for continuity, and all mechanical connections for leakage. (b) You must install, operate, and maintain each CPMS for a wet scrubber according to the requirements in paragraphs (b)(1) through (3) of this section. (1) Each CPMS must complete a minimum of one cycle of operation for each successive 15-minute period. (2) Each CPMS must have valid data for at least 95 percent of every averaging period. (3) Each CPMS must determine and record the hourly average of all recorded readings.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.