§ 86.518-78 Dynamometer calibration.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 86.518-78, § 86.518-78 Dynamometer calibration, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/179779
- Permanent ID
ys:prov:179779@1- SHA-256
4ba90171c28ac52700d5b5087e56c7a9111a44db9514e5b2c1e16c89f978d048
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The dynamometer shall be calibrated at least once each month or performance verified at least once each week and then calibrated as required. The dynamometer is driven above the test speed range. The device used to drive the dynamometer is then disengaged from the dynamometer and the roll is allowed to coast down. The kinetic energy of the system is dissipated by the dynamometer. This method neglects the variations in roll bearing friction due to the drive axle weight of the vehicle.
(b) Calibration shall consist of coasting down the dynamometer for each inertia load combination used. Coastdown times for the interval from 70 to 60 km/h shall be within the tolerances specified in § 86.529. The dynamometer adjustments necessary to produce these results shall be noted for future reference.
(c) The performance check consists of conducting a dynamometer coastdown at one or more inertia-horsepower settings and comparing the coastdown time to the table in Figure F98-9 of § 86.529-98. If the coastdown time is outside the tolerance, a new calibration is required.