40 CFR — Protection of Environment

Appendix IX to Part 86—Experimentally Determining the R-Factor for Bench Aging Durability Procedures

United States · 40 CFR — Protection of Environment · Status: effective

Get this as JSONEmbed this
Cite this
Citation
40 CFR — Protection of Environment, Appendix IX to Part 86—Experimentally Determining the R-Factor for Bench Aging Durability Procedures, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/179941
Permanent ID
ys:prov:179941@1
SHA-256
9d79fff706d56a5fc51f96bde9a35b3ed80ec890040677f3775539149743e6fc

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

The R-Factor is the catalyst thermal reactivity coefficient used in the bench aging time (BAT) equation [Ref. § 86.1826-08(d)(3)]. Manufacturers may determine the value of R experimentally using the following procedures. 1. Using the applicable bench cycle and aging bench hardware, age several catalysts (minimum of 3 of the same catalyst design) at different control temperatures between the normal operating temperature and the damage limit temperature. Measure emissions (or catalyst inefficiency (1-catalyst efficiency)) for each constituent. Assure that the final testing yields data between one- and two-times the standard. 2. Estimate the value of R and calculate the effective reference temperature (Tr) for the bench aging cycle for each control temperature according to the procedure described in § 86.1826-08(d)(4). 3. Plot emissions (or catalyst inefficiency) versus aging time for each catalyst. Calculate the least-squared best-fit line through the data. For the data set to be useful for this purpose the data should have an approximately common intercept between 0 and 4000 miles. See the following graph for an example. 4. Calculate the slope of the best-fit line for each aging temperature. 5. Plot the natural log (ln) of the slope of each best-fit line (determined in step 4) along the vertical axis, versus the inverse of aging temperature (1/(aging temperature, deg K)) along the horizontal axis, Calculate the least-squared best-fit lines through the data. The slope of the line is the R-factor. See the following graph for an example. 6. Compare the R-factor to the initial value that was used in Step 2. If the calculated R-factor differs from the initial value by more than 5%, choose a new R-factor that is between the initial and calculated values, then repeat Steps 2-6 to derive a new R-factor. Repeat this process until the calculated R-factor is within 5% of the initially assumed R-factor. 7. Compare the R-factor determined separately for each constituent. Use the lowest R-factor (worst case) for the BAT equation.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.