yourstate.us
40 CFR 143.12

§ 143.12 Definition of lead free and calculation methodology.

United States · 40 CFR — Protection of Environment · Status: effective

Get this as JSONEmbed this
Cite this
Citation
40 CFR 143.12, § 143.12 Definition of lead free and calculation methodology, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/182191
Permanent ID
ys:prov:182191@1
SHA-256
8926b209a8f1982871ed4ef55ee3c082d551eca1c3866851f7bc7702927bd089

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) “Lead free” for the purposes of this subpart means: (1) Not containing more than 0.2 percent lead when used with respect to solder and flux; and (2) Not more than a weighted average of 0.25 percent lead when used with respect to the wetted surfaces of pipes, pipe fittings, plumbing fittings, and fixtures. (b) The weighted average lead content of a pipe, pipe fitting, plumbing fitting, or fixture is calculated by using the following formula: For each wetted component, the percentage of lead in the component is multiplied by the ratio of the wetted surface area of that component to the total wetted surface area of the entire product to arrive at the weighted percentage of lead of the component. The weighted percentage of lead of each wetted component is added together, and the sum of these weighted percentages constitutes the weighted average lead content of the product. The lead content of the material used to produce wetted components is used to determine compliance with paragraph (a)(2) of this section. For lead content of materials that are provided as a range, the maximum content of the range must be used. (c) If a coating, as defined in § 143.11, is applied to the internal surfaces of a pipe, fitting or fixture component, the maximum lead content of both the coating and the alloy must be used to calculate the lead content of the component. (d) If a liner, as defined in § 143.11, is manufactured into a pipe, fitting or fixture, the maximum lead content of the liner must be used to calculate the lead content of the component. (e) If a fixture contains any media (e.g., activated carbon, ion exchange resin) contained in filters, the media are not to be used in determining the “total wetted surface area of the entire product” in paragraph (b) of this section. (f) In addition to the definitions of “lead free” in paragraphs (a) through (e) of this section, no drinking water cooler, which contains any solder, flux, or storage tank interior surface, which may come into contact with drinking water, is lead free if the solder, flux, or storage tank interior surface contains more than 0.2 percent lead. Drinking water coolers must be manufactured such that each individual part or component that may come in contact with drinking water shall not contain more than 8 percent lead while still meeting the maximum 0.25 percent weighted average lead content of the wetted surfaces of the entire product.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.