§ 261.194 General operating requirements.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 261.194, § 261.194 General operating requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/185359
- Permanent ID
ys:prov:185359@1- SHA-256
53fd7fbe7ed147861546909bcdac0c9e2d28408b1915ec20ac37d4b0917687d9
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Hazardous secondary materials or treatment reagents must not be placed in a tank system if they could cause the tank, its ancillary equipment, or the containment system to rupture, leak, corrode, or otherwise fail.
(b) The remanufacturer or other person that stores or treats the hazardous secondary material must use appropriate controls and practices to prevent spills and overflows from tank or containment systems. These include at a minimum:
(1) Spill prevention controls (e.g., check valves, dry disconnect couplings);
(2) Overfill prevention controls (e.g., level sensing devices, high level alarms, automatic feed cutoff, or bypass to a standby tank); and
(3) Maintenance of sufficient freeboard in uncovered tanks to prevent overtopping by wave or wind action or by precipitation.
(c) The remanufacturer or other person that stores or treats the hazardous secondary material must comply with the requirements of § 261.196 of this subpart if a leak or spill occurs in the tank system.