40 CFR 261.1055
§ 261.1055 Standards: Sampling connection systems.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 261.1055, § 261.1055 Standards: Sampling connection systems, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/185387
- Permanent ID
ys:prov:185387@1- SHA-256
12c600091db2485305f77c28b14ddd84d69000ca585fd6457dfbd90f05bb2205
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Each sampling connection system shall be equipped with a closed-purge, closed-loop, or closed-vent system. This system shall collect the sample purge for return to the process or for routing to the appropriate treatment system. Gases displaced during filling of the sample container are not required to be collected or captured.
(b) Each closed-purge, closed-loop, or closed-vent system as required in paragraph (a) of this section shall meet one of the following requirements:
(1) Return the purged process fluid directly to the process line;
(2) Collect and recycle the purged process fluid; or
(3) Be designed and operated to capture and transport all the purged process fluid to a material management unit that complies with the applicable requirements of §§ 261.1084 through 264.1086 of this subpart or a control device that complies with the requirements of § 261.1060 of this subpart.
(c) In-situ sampling systems and sampling systems without purges are exempt from the requirements of paragraphs (a) and (b) of this section.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.