40 CFR 267.73
§ 267.73 What information must I keep?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 267.73, § 267.73 What information must I keep?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/186147
- Permanent ID
ys:prov:186147@1- SHA-256
fda6edc0900848f01276ca3cfdbd7131aab05a0e3adf74c86382775db086b328
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) You must keep a written operating record at your facility.
(b) You must record the following information, as it becomes available, and maintain the operating record until you close the facility:
(1) A description and the quantity of each type of hazardous waste generated, and the method(s) and date(s) of its storage and/or treatment at the facility as required by Appendix I of 40 CFR part 264;
(2) The location of each hazardous waste within the facility and the quantity at each location;
(3) Records and results of waste analyses and waste determinations you perform as specified in §§ 267.13, 267.17, and 40 CFR 264.1034, 264.1063, 264.1083, and 268.7;
(4) Summary reports and details of all incidents that require you to implement the contingency plan as specified in § 267.58(b));
(5) Records and results of inspections as required by § 267.15(d) (except you need to keep these data for only three years);
(6) Monitoring, testing or analytical data, and corrective action when required by subpart F of this part and §§ 267.191, 267.193, 267.195, and 40 CFR 264.1034(c) through 264.1034(f), 264.1035, 264.1063(d) through 264.1063(i), 264.1064, 264.1088, 264.1089, and 264.1090;
(7) All closure cost estimates under § 267.142;
(8) Your certification, at least annually, that you have a program in place to reduce the volume and toxicity of hazardous waste that you generate to the degree that you determine to be economically practicable; and that the proposed method of treatment or storage is that practicable method currently available to you that minimizes the present and future threat to human health and the environment;
(9) For an on-site treatment facility, the information contained in the notice (except the manifest number), and the certification and demonstration, if applicable, required by you under 40 CFR 268.7; and
(10) For an on-site storage facility, the information in the notice (except the manifest number), and the certification and demonstration, if applicable, required by you under 40 CFR 268.7.
(11) For an off-site treatment facility, a copy of the notice, and the certification and demonstration, if applicable, required by the generator or the owner or operator under § 268.7 or § 268.8;
(12) For an off-site storage facility, a copy of the notice, and the certification and demonstration, if applicable, required by the generator or the owner or operator under § 268.7 or § 268.8.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.