§ 267.1103 What additional design and operating standards apply if liquids will be in my containment building?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 267.1103, § 267.1103 What additional design and operating standards apply if liquids will be in my containment building?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/186205
- Permanent ID
ys:prov:186205@1- SHA-256
4415c6f866cb96379998657725eedba1267d79d2191fe12b1e2083d58b947c4a
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
If your containment building will be used to manage hazardous wastes containing free liquids or treated with free liquids, as determined by the paint filter test, by a visual examination, or by other appropriate means, you must include:
(a) A primary barrier designed and constructed of materials to prevent the migration of hazardous constituents into the barrier (for example, a geomembrane covered by a concrete wear surface).
(b) A liquid collection and removal system to minimize the accumulation of liquid on the primary barrier of the containment building.
(1) The primary barrier must be sloped to drain liquids to the associated collection system; and
(2) You must collect and remove liquids and waste to minimize hydraulic head on the containment system at the earliest practicable time.
(c) A secondary containment system, including a secondary barrier designed and constructed to prevent migration of hazardous constituents into the barrier, and a leak detection system capable of detecting failure of the primary barrier and collecting accumulated hazardous wastes and liquids at the earliest practical time.
(1) You may meet the requirements of the leak detection component of the secondary containment system by installing a system that is, at a minimum:
(i) Constructed with a bottom slope of 1 percent or more; and
(ii) Constructed of a granular drainage material with a hydraulic conductivity of 1 × 10−2 cm/sec or more and a thickness of 12 inches (30.5 cm) or more, or constructed of synthetic or geonet drainage materials with a transmissivity of 3 × 10-5 m 2sec or more.
(2) If you will be conducting treatment in the building, you must design the area in which the treatment will be conducted to prevent the release of liquids, wet materials, or liquid aerosols to other portions of the building.
(3) You must construct the secondary containment system using materials that are chemically resistant to the waste and liquids managed in the containment building and of sufficient strength and thickness to prevent collapse under the pressure exerted by overlaying materials and by any equipment used in the containment building.