40 CFR 267.1106
§ 267.1106 What do I do if I detect a release?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 267.1106, § 267.1106 What do I do if I detect a release?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/186208
- Permanent ID
ys:prov:186208@1- SHA-256
9ad50238b9c300fdd0e9ab0ebf1b78b5872b212bc0eb482428c8ec0e94fefb47
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Throughout the active life of the containment building, if you detect a condition that could lead to or has caused a release of hazardous waste, you must repair the condition promptly, in accordance with the following procedures.
(a) Upon detection of a condition that has lead to a release of hazardous waste (for example, upon detection of leakage from the primary barrier), you must:
(1) Enter a record of the discovery in the facility operating record;
(2) Immediately remove the portion of the containment building affected by the condition from service;
(3) Determine what steps you must take to repair the containment building, to remove any leakage from the secondary collection system, and to establish a schedule for accomplishing the cleanup and repairs; and
(4) Within 7 days after the discovery of the condition, notify the Regional Administrator of the condition, and within 14 working days, provide a written notice to the Regional Administrator with a description of the steps taken to repair the containment building, and the schedule for accomplishing the work.
(b) The Regional Administrator will review the information submitted, make a determination regarding whether the containment building must be removed from service completely or partially until repairs and cleanup are complete, and notify you of the determination and the underlying rationale in writing.
(c) Upon completing all repairs and cleanup, you must notify the Regional Administrator in writing and provide a verification, signed by a qualified, registered professional engineer, that the repairs and cleanup have been completed according to the written plan submitted in accordance with paragraph (a)(4) of this section.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.