40 CFR 279.55
§ 279.55 Analysis plan.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 279.55, § 279.55 Analysis plan, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/186641
- Permanent ID
ys:prov:186641@1- SHA-256
6e4054528c6c1f4472d7750b261b337578fedcfbd34eb33077423a5c9e2f0387
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Owners or operators of used oil processing and re-refining facilities must develop and follow a written analysis plan describing the procedures that will be used to comply with the analysis requirements of § 279.53 and, if applicable, § 279.72. The owner or operator must keep the plan at the facility.
(a) Rebuttable presumption for used oil in § 279.53. At a minimum, the plan must specify the following:
(1) Whether sample analyses or knowledge of the halogen content of the used oil will be used to make this determination.
(2) If sample analyses are used to make this determination:
(i) The sampling method used to obtain representative samples to be analyzed. A representative sample may be obtained using either:
(A) One of the sampling methods in appendix I of part 261 of this chapter; or
(B) A method shown to be equivalent under §§ 260.20 and 260.21 of this chapter;
(ii) The frequency of sampling to be performed, and whether the analysis will be performed on-site or off-site; and
(iii) The methods used to analyze used oil for the parameters specified in § 279.53; and
(3) The type of information that will be used to determine the halogen content of the used oil.
(b) On-specification used oil fuel in § 279.72. At a minimum, the plan must specify the following if § 279.72 is applicable:
(1) Whether sample analyses or other information will be used to make this determination;
(2) If sample analyses are used to make this determination:
(i) The sampling method used to obtain representative samples to be analyzed. A representative sample may be obtained using either:
(A) One of the sampling methods in appendix I of part 261 of this chapter; or
(B) A method shown to be equivalent under §§ 260.20 and 260.21 of this chapter;
(ii) Whether used oil will be sampled and analyzed prior to or after any processing/re-refining;
(iii) The frequency of sampling to be performed, and whether the analysis will be performed on-site or off-site; and
(iv) The methods used to analyze used oil for the parameters specified in § 279.72; and
(3) The type of information that will be used to make the on-specification used oil fuel determination.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.