40 CFR 761.243
§ 761.243 Standard wipe sample method and size.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 761.243, § 761.243 Standard wipe sample method and size, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/194356
- Permanent ID
ys:prov:194356@1- SHA-256
d00f3e1c4878ed8f23e3302fdbbcecce7de35685e39bb59f2c4a6bd7d0e5000b
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Collect a surface sample from a natural gas pipe segment or pipeline section using a standard wipe test as defined in § 761.123. Detailed guidance for the entire wipe sampling process appears in the document entitled, “Wipe Sampling and Double Wash/Rinse Cleanup as Recommended by the Environmental Protection Agency PCB Spill Cleanup Policy,” dated June 23, 1987, and revised on April 18, 1991. This document is available on EPA's website at https://www.epa.gov/pcbs, or from the Program Implementation and Information Division, Office of Resource Conservation and Recovery (5303T), Environmental Protection Agency, 1200 Pennsylvania Ave. NW, Washington, DC 20460-0001.
(b) Collect a surface sample from a minimum surface area of 100 cm 2 at each sampling site selected. The EPA Regional Administrator may approve, in writing, requests to collect a sample from smaller surface areas, when <100 cm 2 of surface eligible for sampling is present; e.g., when sampling a small diameter pipe, a small valve, or a small regulator. When smaller surfaces are sampled, convert the measurement to the equivalent measurement for 100 cm 2 for purposes of comparison to standards based on 100 cm 2.