40 CFR 761.326
§ 761.326 Conducting the comparison study.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 761.326, § 761.326 Conducting the comparison study, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/194389
- Permanent ID
ys:prov:194389@1- SHA-256
c0e9dbc6b41d2c943d9ed1371f4dc72b153f73a77398cc66537047a7add16fef
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
Extract or analyze the comparison study samples using the alternative method. For an alternative extraction method or alternative analytical method to be comparable to the methods required in § 761.292, all of the following conditions must be met.
(a) All samples having PCB concentrations greater than or equal to the level of concern, as measured by the methods required in § 761.292, are found to be greater than or equal to the level of concern as measured by the alternative method (no false negatives).
(b) Only one sample which contains PCBs at a level less than the level of concern, as measured by the methods required in § 761.292, is found to have a PCB concentration greater than the level of concern as measured by the alternative method (false positive); and all other samples which contain PCBs at levels less than the level of concern, as measured by the methods required in § 761.292, are found by the alternative method to have PCBs less than the level of concern (there are no additional false positives).