§ 766.18 Method sensitivity.
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 766.18, § 766.18 Method sensitivity, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/194473
- Permanent ID
ys:prov:194473@1- SHA-256
db73f07fe9d17677a3b2db7d1b7fe3e5876dad680b9b9c51cf4be6cc63a9369d
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The target level of quantitation required under § 766.27 for each HDD/HDF congener is the level which must be attempted for each resolved HRGC peak for that congener. For at least one product sample, at least two analyses of the same isotopically labeled HDD/HDF internal calibration standards spiked to a final product concentration equal to the LOQ for that congener must be reproducibly extracted, cleaned up, and quantified to within ±20 percent of each other. For each spiked product sample, the signal to noise ratio for the calibration standard peaks after complete extraction and cleanup must be 10:1 or greater. The recovery of the internal calibration standards in the extracted and cleaned up product samples must be within 50 to 150 percent of the amount spiked, and the results must be corrected for recovery.