40 CFR 1045.706
§ 1045.706 How do I generate and calculate evaporative emission credits?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 1045.706, § 1045.706 How do I generate and calculate evaporative emission credits?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/195346
- Permanent ID
ys:prov:195346@1- SHA-256
b467c30d938f4eb413edad14f57e9e8493804d4e77aba1a1f20401d73f19d6b3
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
The provisions of this section apply for calculating evaporative emission credits. This applies only for fuel tank permeation. You may generate credits only if you are a certifying vessel manufacturer. This may include outboard engine manufacturers if they install under-cowl fuel tanks.
(a) For each participating vessel, calculate positive or negative emission credits relative to the otherwise applicable emission standard. Calculate positive emission credits for a family that has an FEL below the standard. Calculate negative emission credits for a family that has an FEL above the standard. Sum your positive and negative credits for the model year before rounding. Round the sum of emission credits to the nearest kilogram (kg) using consistent units throughout the following equation:
Where:
(b) For calculating credits under paragraph (a) of this section, the emission standard and FEL must both be based on test measurements at the same temperature (28 ° or 40 °C). Determine the FEL for calculating emission credits (relative to testing at 28 °C) as follows:
(1) To use an FEL below 5.0 g/m 2/day, it must be based on emission measurements.
(2) The provisions of this paragraph (b)(2) apply for all emission families with FELs at or above 5.0 g/m 2/day. To calculate emission credits for such emission families, you must choose from one of the following options and apply it to all your emission families with FELs at or above 5.0 g/m 2/day:
(i) Option 1: Establish all your FELs based on emission measurements. This may include measurements from a certifying fuel tank manufacturer.
(ii) Option 2: Use an assigned FEL of 10.4 g/m 2/day. This would apply without regard to whether any of these emission families have measured emission levels below 10.4 g/m 2/day. If any of your fuel tanks were otherwise certified (by you or the fuel tank manufacturer) with an FEL between 5.0 and 10.4 g/m 2/day, the assigned FEL of 10.4 g/m 2/day applies only for emission credit calculations.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.