40 CFR 1060.521
§ 1060.521 How do I test fuel caps for permeation emissions?
United States · 40 CFR — Protection of Environment · Status: effective
Cite this
- Citation
- 40 CFR 1060.521, § 1060.521 How do I test fuel caps for permeation emissions?, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/195652
- Permanent ID
ys:prov:195652@1- SHA-256
bfa4250ad18b7b1fa840851b018703caf65e1ba5ad1134b9282411901e4f06c4
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
If you measure a fuel tank's permeation emissions with a nonpermeable covering in place of the fuel cap under § 1060.520(b)(5)(ii)(B), you must separately measure permeation emissions from a fuel cap. You may show that your fuel tank and fuel cap meet emission standards by certifying them separately or by combining the separate measurements into a single emission rate based on the relative surface areas of the fuel tank and fuel cap. However, you may not combine these emission measurements if you test the fuel cap at a nominal temperature of 28 °C and you test the fuel tank at 40 °C. Measure the fuel cap's permeation emissions as follows:
(a) Select a fuel cap expected to have permeation emissions at least as high as the highest-emitting fuel cap that you expect to be used with fuel tanks from the emission family. Include a gasket that represents production models. If the fuel cap includes vent paths, seal these vents as follows:
(1) If the vent path is through grooves in the gasket, you may use another gasket with no vent grooves if it is otherwise the same as a production gasket.
(2) If the vent path is through the cap, seal any vents for testing.
(b) Attach the fuel cap to a fuel tank with a capacity of at least one liter made of metal or some other impermeable material.
(c) Use the procedures specified in § 1060.520 to measure permeation emissions. Calculate emission rates using the smallest inside cross sectional area of the opening on which the cap is mounted as the fuel cap's surface area.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.