40 CFR 1065.255

§ 1065.255 H

United States · 40 CFR — Protection of Environment · Status: effective

Get this as JSONEmbed this
Cite this
Citation
40 CFR 1065.255, § 1065.255 H, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/195706
Permanent ID
ys:prov:195706@1
SHA-256
792d1fb577f3dcc854081eaa9fe198503a3c2b0f9e9d377ea80142c277a3bdbd

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Component requirements. We recommend that you use an analyzer that meets the specifications in § 1065.205. Note that your system must meet the linearity verification in § 1065.307. (b) Instrument types. You may use any of the following analyzers to measure H2: (1) Magnetic sector mass spectrometer. (2) Raman spectrometer. (c) Interference verification. Certain compounds can positively interfere with magnetic sector mass spectroscopy and raman spectroscopy by causing a response similar to H2. Use good engineering judgment to determine interference species when performing interference verification. In the case of raman spectroscopy, determine interference species that are appropriate for each H2 infrared absorption band, or you may identify the interference species based on the instrument manufacturer's recommendations.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.