§ 84.84 Hand-operated valves; minimum requirements.

United States · 42 CFR — Public Health · Status: effective

Get this as JSONEmbed this
Cite this
Citation
42 CFR 84.84, § 84.84 Hand-operated valves; minimum requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201701
Permanent ID
ys:prov:201701@1
SHA-256
23a49a84f550f63e5472f12dd053fefc34af9e7cc476b6a55b1d39f358b5d38d

The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.

Full text

(a) Hand-operated valves shall be designed and constructed to prevent removal of the stem from the valve body during normal usage to insure against a sudden release of the full pressure of the container when the valve is opened. (b) Valves shall be designed or positioned to prevent accidental opening and closing, and damage from external forces. (c) Valves operated during use of the apparatus shall be installed in locations where they can be readily adjusted by the wearer. (d) Main-line valves, designed and constructed to conserve gas in the event of a regulator or demand valve failure, shall be provided in addition to gas container valves, except when such failure will not affect performance. (e) Hand-operated bypass systems designed and constructed to permit the wearer to breathe and to conserve his gas supply in the event of a regulator or demand valve failure, shall be provided where necessary. (f) Valves installed on apparatus shall be clearly distinguishable from one another by sight and touch. (g) The bypass system valve control shall be colored red. (h) A main-line or bypass valve or system will not be required on apparatus for escape only. (i) Safety relief valves or systems, designed and constructed to release excess pressure in the breathing circuit, shall be provided on closed-circuit apparatus, and shall meet the following requirements: (1) The relief valve or system shall operate automatically when the pressure in the breathing circuit on the inhalation side of the breathing bag reaches 13 mm. (one-half inch) water-column height of pressure above the minimum pressure required to fill the breathing bag, within the breathing resistance requirements for the apparatus. (2) The relief valve or system shall be designed to prevent external atmospheres from entering the breathing circuit. (3) The relief valve or system shall be designed to permit manual overriding for test purposes and in the event of a failure in the valve or system.

Legislative history

This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.