42 CFR 84.88
§ 84.88 Breathing bag test.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.88, § 84.88 Breathing bag test, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201705
- Permanent ID
ys:prov:201705@1- SHA-256
9d5103ed361f6d8808f9752890e3ca48cfa73a6613d23f731d496b6cb36367d4
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Breathing bags will be tested in an air atmosphere saturated with gasoline vapor at room temperature (24-30 °C./75-85 °F.) for a continuous period of twice the rated time of the apparatus (except for apparatus for escape only where the test period shall be the rated time of the apparatus).
(b) The bag will be operated during this test by a breathing machine with 24 respirations per minute and a minute-volume of 40 liters.
(c) A breathing machine cam with a work rate of 622 kp.-m./min. will be used. The dimensions of a suitable breathing machine cam are available from the Institute upon request.
(d) The air within the bag(s) shall not contain more than 100 parts per million of gasoline vapor at the end of the test.
Legislative history