§ 84.90 Breathing resistance test; inhalation.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.90, § 84.90 Breathing resistance test; inhalation, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201707
- Permanent ID
ys:prov:201707@1- SHA-256
4687e37dee320fed8a98d0e9a3c4b2971178134593f2e65158ebc5a3eb44bc93
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Resistance to inhalation airflow will be measured in the facepiece or mouthpiece while the apparatus is operated by a breathing machine as described in § 84.88.
(b) The inhalation resistance of open-circuit apparatus shall not exceed 32 mm. (1.25 inch) water-column height (at a flow rate of 120 liters per minute).
(c) The inhalation resistance of closed-circuit apparatus shall not exceed the difference between exhalation resistance (§ 84.91(e)) and 10 cm. (4 inches) water-column height.