42 CFR 84.124
§ 84.124 Facepiece tests; minimum requirements.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.124, § 84.124 Facepiece tests; minimum requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201738
- Permanent ID
ys:prov:201738@1- SHA-256
a0e53ea2796bfadb7c51244dc8f58e5536a25b310edca9b6c668d55ade374262
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) The complete gas mask will be fitted to the faces of persons having varying facial shapes and sizes.
(b) Where the applicant specifies a facepiece size or sizes for the gas mask, together with the approximate measurements of faces they are designed to fit, the Institute will insure that test subjects suit such facial measurements.
(c) Any gas mask parts which must be removed to perform the facepiece or mouthpiece fit test shall be replaceable without special tools and without disturbing the facepiece or mouthpiece fit.
(d) The facepiece or mouthpiece fit test, using positive or negative pressure recommended by the applicant and described in his instructions will be used before each test specified in paragraph (e) of this section, and in § 84.125.
(e)(1) Each wearer will enter a chamber containing 100 p.p.m. isoamyl acetate vapor for a half-mask facepiece and 1,000 p.p.m. isoamyl acetate vapor for a full facepiece or mouthpiece.
(2) The facepiece or mouthpiece may be adjusted, if necessary, in the test chamber before starting the tests.
(3) Each wearer will remain in the chamber for 8 minutes while performing the following activities:
(i) Two minutes, nodding and turning head;
(ii) Two minutes, calisthenic arm movements;
(iii) Two minutes, running in place; and
(iv) Two minutes, pumping with a tire pump into a 28 liter (1 cubic foot) container.
(4) Each wearer shall not detect the odor of isoamyl acetate during the test.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.