42 CFR 84.143
§ 84.143 Terminal fittings or chambers; Type B supplied-air respirators; minimum requirements.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.143, § 84.143 Terminal fittings or chambers; Type B supplied-air respirators; minimum requirements, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201756
- Permanent ID
ys:prov:201756@1- SHA-256
a95f800e6b384c38902dfedcf2c2f55aa4995bebc6e501d550e0efb3ac5c5d04
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
(a) Blowers or connections to air supplies providing positive pressures shall not be approved for use on Type B supplied-air respirators.
(b) Terminal fittings or chambers employed in Type B supplied-air respirators, shall be:
(1) Installed in the inlet of the hose.
(2) Designed and constructed to provide for the drawing of air through corrosion resistant material arranged so as to be capable of removing material larger than 0.149 mm. in diameter (149 micrometers, 100-mesh, U.S. Standard sieve).
(3) Installed to provide a means for fastening or anchoring the fitting or chamber in a fixed position in a zone of respirable air.