42 CFR 84.146
§ 84.146 Method of measuring the power and torque required to operate blowers.
United States · 42 CFR — Public Health · Status: effective
Cite this
- Citation
- 42 CFR 84.146, § 84.146 Method of measuring the power and torque required to operate blowers, United States, version 1 as recorded 2026-07-09, yourstate.us, https://yourstate.us/provision/201759
- Permanent ID
ys:prov:201759@1- SHA-256
00048fe5eb352dfdaa45d627f8f5ef4069548473ea613c94c1d375f8fd659b17
The hash is SHA-256 of this version's text, with every run of whitespace collapsed to a single space and the ends trimmed. The ID always leads back here, and checking it says whether the text you cited is still the current version.
Full text
As shown in Figure 1 of this section, the blower crank is replaced by a wooden drum, a (13 cm. (5 inches) in diameter is convenient). This drum is wound with about 12 m. (40 feet) of No. 2 picture cord, b. A weight, c, of sufficient mass to rotate the blower at the desired speed is suspended from this wire cord. A mark is made on the cord about 3 to 4.5 m. (10 to 15 feet) from the weight, c. Another mark is placed at a measured distance (6-9 m./20-30 feet is convenient) from the first. These are used to facilitate timing. To determine the torque or horsepower required to operate the blower, the drum is started in rotation manually at or slightly above the speed at which the power measurement is to be made. The blower is then permitted to assume constant speed, and then as the first mark on the wire leaves the drum, a stopwatch is started. The watch is stopped when the second mark leaves the drum. From these data the foot-pounds per minute and the torque may be calculated.
Legislative history
This is a federal regulation, adopted through agency rulemaking under the Administrative Procedure Act — not enacted by a recorded vote of Congress.